Time periods of oscillation of the same simple pendulum measured using four different measuring clocks were recorded as and . The arithmetic mean of these readings in correct significant figure is :
- A
- B
- C
- D
Errors in measurement and significant figures has been asked 75 times in JEE Main, in 16 different years between 2008 and 2026, and in all of the last five exam years (2022–2026), 42 questions in all. That is 34% of Units, Dimensions & Errors, one of its three most-asked topics. Last asked in JEE Main 06 Apr 2026, Shift 2. 63 are multiple choice and 12 numerical-value; 29 easy, 40 medium and 1 hard by our difficulty labels. All of them are below, newest first, free to read.
Questions
75
Years asked
16
Since
2008
Of the chapter
34%
21–40 OF 75 · NEWEST FIRST
Time periods of oscillation of the same simple pendulum measured using four different measuring clocks were recorded as and . The arithmetic mean of these readings in correct significant figure is :
In an experiment to measure focal length (f) of convex lens, the least counts of the measuring scales for the position of object (u) and for the position of image (v) are and , respectively. The error in the measurement of the focal length of the convex lens will be:
The radius , length and resistance of a metal wire was measured in the laboratory as cm, ohm, cm. The percentage error in resistivity of the material of the wire is :
Match List - I with List - II.
Choose the correct answer from the options given below:
(A)-(III), (B)-(IV), (C)-(II), (D)-(I)
(A)-(IV), (B)-(III), (C)-(I), (D)-(II)
(A)-(II), (B)-(I), (C)-(IV), (D)-(III)
(A)-(I), (B)-(II), (C)-(III), (D)-(IV)
If the percentage errors in measuring the length and the diameter of a wire are each. The percentage error in measuring its resistance will be:
The measured value of the length of a simple pendulum is 20 cm with 2 mm accuracy. The time for 50 oscillations was measured to be 40 seconds with 1 second resolution. From these measurements, the accuracy in the measurement of acceleration due to gravity is %. The value of is:
4
8
6
5
The resistance , where V and A, the percentage error in the measurement of is :
A physical quantity is found to depend on quantities by the relation . The percentage error in and are and respectively. Then, the percentage error in is:
A body of mass kg is moving with a velocity of m s. Its kinetic energy will be
J
J
J
J
A physical quantity is given as . The percentage error in the measurement of , , and are 1%, 2%, 3% and 4% respectively. The percentage error in the measurement of quantity will be
13%
16%
12%
14%
A cylindrical wire of mass g has length cm and radius mm. The maximum error in its density will be
3.5%
5%
1%
4%
Two resistances are given as and . The percentage error in the measurement of equivalent resistance when they are connected in parallel is
6.33
2.33
5.33
4.33
A 2 meter long scale with least count of 0.2 cm is used to measure the locations of objects on an optical bench. While measuring the focal length of a convex lens, the object pin and the convex lens are placed at 80 cm mark and 1 m mark, respectively. The image of the object pin on the other side of lens coincides with image pin that is kept at 180 cm mark. The % error in the estimation of focal length is:
0.85
1.70
1.02
0.51
In an experiment for estimating the value of focal length of converging mirror, image of an object placed at cm from the pole of the mirror is formed at distance cm from the pole of the mirror. These distances are measured with a modified scale in which there are 20 small divisions in cm. The value of error in measurement of focal length of the mirror is cm. The value of is ______.
In an experiment to find acceleration due to gravity using simple pendulum, time period of 0.5 s is measured from time of 100 oscillation with a watch of 1 s resolution. If measured value of length is 10 cm known to 1 mm accuracy. The accuracy in the determination of is found to be . The value of is
A torque meter is calibrated to reference standards of mass, length and time each with accuracy. After calibration, the measured torque with this torque meter will have net accuracy of
In an experiment to determine the Young's modulus of wire of a length exactly , the extension in the length of the wire is measured as with an uncertainty of when a load of is applied. The diameter of the wire is measured as with an uncertainty of . The error in the measurement of Young's modulus is found to be . The value of is ______.
The maximum error in the measurement of resistance, current and time for which current flows in an electrical circuit are , and respectively. The maximum percentage error in the detection of the dissipated heat will be:
A student in the laboratory measures thickness of a wire using screw gauge. The readings are 1.22 mm, 1.23 mm, 1.19 mm and 1.20 mm. The percentage error is %. The value of is ______.
A silver wire has a mass g, radius mm and length cm. The maximum percentage error in the measurement of its density will be