The lead storage battery has two lead-based electrodes dipped in H2SO4.
• Spongy lead plate → traditionally called the anode plate.
• Lead dioxide plate → traditionally called the cathode plate.
While discharging, the following galvanic half-reactions take place:
Atanode(Pb):Pb(0)+SO42−→PbSO4(Pb2+)+2e−
Atcathode(PbO2):PbO2(Pb4+)+SO42−+4H++2e−→PbSO4(Pb2+)+2H2O
When the battery is CHARGED, an external emf forces the reactions to run in the reverse direction (electrolysis).
Therefore:
Case for the anode plate (spongy lead)
Reverse of the discharge reaction:
PbSO4(Pb2+)+2e−→Pb(0)+SO42−
Thus, at the anode plate the oxidation state of lead changes
from x1=+2 (in PbSO4) to y1=0 (in metallic Pb).
Case for the cathode plate (lead dioxide)
Reverse of the discharge reaction:
PbSO4(Pb2+)+2H2O→PbO2(Pb4+)+SO42−+4H++2e−
Hence, at the cathode plate the oxidation state of lead changes
from x2=+2 (in PbSO4) to y2=+4 (in PbO2).
Collecting the four values:
x1=+2,y1=0,x2=+2,y2=+4
These correspond to Option B.
Final answer: +2,0,+2,+4 (Option B).