We have a moving-coil galvanometer whose resistance is Rg=100Ω. The scale has 50 divisions and the current sensitivity is 20μA per division.
First we find the full-scale (maximum) current of the galvanometer. Since each division needs 20μA and there are 50 divisions, we write
Ig=50×20μA=50×20×10−6 A=1000μA=1mA.
To convert the galvanometer into a voltmeter, we keep the current through it limited to this same Ig=1mA while different external voltages are applied. For each desired range we first write Ohm’s law, V=IR, then solve for the total resistance that must be in series with the galvanometer.
For the 0 - 2 V range, the total resistance required is
R2V (total)=IgV=0.001A2V=2000Ω.
This total already includes the galvanometer’s 100 Ω, so the series resistance needed is
Rs1=R2V (total)−Rg=2000−100=1900Ω.
For the 0 - 10 V range, the total resistance required is
R10V (total)=0.001A10V=10000Ω,
and therefore the series resistance for this range alone must satisfy
Rs(10)=R10V (total)−Rg=10000−100=9900Ω.
For the 0 - 20 V range, the total resistance required is
R20V (total)=0.001A20V=20000Ω,
so the required series resistance is
Rs(20)=R20V (total)−Rg=20000−100=19900Ω.
In a multirange voltmeter the usual practice is to place resistors in series such that:
- Only the first resistor is used for the 2 V range,
- The first and the second together are used for the 10 V range,
- All three resistors are used for the 20 V range.
Let these resistors be R1,R2,R3 connected sequentially with R1 closest to the galvanometer. Then we require
R1R1+R2R1+R2+R3=1900Ω,=9900Ω⟹R2=9900−1900=8000Ω,=19900Ω⟹R3=19900−9900=10000Ω.
This gives the set R1=1900Ω,R2=8000Ω,R3=10000Ω, with the ranges obtained in the order 2 V, 10 V, 20 V as required.
Comparing these values with the options, we see that they match exactly with Option D.
Hence, the correct answer is Option D.