We start with the information for the first solution.
Its resistance is given as R1=50Ω and its specific conductance (also called conductivity) is κ1=1.4S m−1.
The relation that links the conductivity κ, the conductance G and the cell constant Aℓ is first stated:
κ=G(Aℓ)
and
G=R1.
So, for the first solution we have
G1=R11=501S.
Substituting this value in the conductivity formula, we get the cell constant:
Aℓ=G1κ1=κ1×R1=1.4×50=70m−1.
The cell constant is a property of the conductivity cell, so it remains the same when we measure the second solution.
Now we turn to the second solution whose resistance is
R2=280Ω.
First we calculate its conductance:
G2=R21=2801S.
Using the same formula κ=G(Aℓ), we find its conductivity κ2:
κ2=G2(Aℓ)=2801×70=28070=0.25S m−1.
The concentration of the second solution is given as 0.5M.
Because 1M=1mol L−1=1000mol m−3, we convert:
c=0.5M=0.5×1000=500mol m−3.
The formula that connects molar conductivity Λm with conductivity κ and concentration c (in mol m−3) is
Λm=cκ.
Substituting the values we have just found,
Λm=5000.25S m2 mol−1=0.0005S m2 mol−1.
Writing the answer in scientific notation,
Λm=5×10−4S m2 mol−1.
Hence, the correct answer is Option A.