Let the common cross-sectional area of the rod be A and let the steady-state temperature at the junction be T.
In steady state the heat current (rate of heat flow) through every cross-section of the rod is the same, because the lateral surface is perfectly insulated. Therefore, the heat current through the first section must equal the heat current through the second section.
Fourier’s law for each section is
Q=ℓkAΔT
First section (length ℓ1, conductivity k1):
Q=ℓ1k1A(T1−T) −(1)
Second section (length ℓ2, conductivity k2):
Q=ℓ2k2A(T−T2) −(2)
Equating −(1) and −(2) and cancelling the common factor A:
ℓ1k1(T1−T)=ℓ2k2(T−T2)
Cross-multiply:
k1ℓ2(T1−T)=k2ℓ1(T−T2)
Expand and collect the terms containing T on one side:
k1ℓ2T1−k1ℓ2T=k2ℓ1T−k2ℓ1T2
k1ℓ2T+k2ℓ1T=k1ℓ2T1+k2ℓ1T2
Factor out T:
T(k1ℓ2+k2ℓ1)=k1ℓ2T1+k2ℓ1T2
Solve for T:
T=k1ℓ2+k2ℓ1k1ℓ2T1+k2ℓ1T2
Comparing with the given options, this is exactly Option C.
Therefore, the temperature at the interface is
Option C which is: k1ℓ2+k2ℓ1k1ℓ2T1+k2ℓ1T2