A transformer operating at primary voltage 8 kV and secondary voltage 160 V serves a load of 80 kW. Assuming the transformer to be ideal with purely resistive load and working on unity power factor, the loads in the primary and secondary circuit would be

SOLUTION

Given, primary voltage Vp=8 kV=8000 VV_p = 8\,\text{kV} = 8000\,\text{V}, secondary voltage Vs=160 VV_s = 160\,\text{V} and load power P=80 kW=80000 WP = 80\,\text{kW} = 80000\,\text{W}.

Since the load is purely resistive, the power factor is 1.

For an ideal transformer, input power is equal to output power.

The secondary current is

Is=PVs=80000160=500 AI_s = \frac{P}{V_s} = \frac{80000}{160} = 500\,\text{A}

Therefore, the load resistance in the secondary circuit is

Rs=VsIs=160500=0.32 ΩR_s = \frac{V_s}{I_s} = \frac{160}{500} = 0.32\,\Omega

The primary current is

Ip=PVp=800008000=10 AI_p = \frac{P}{V_p} = \frac{80000}{8000} = 10\,\text{A}

Therefore, the equivalent load resistance as seen from the primary side is

Rp=VpIp=800010=800 ΩR_p = \frac{V_p}{I_p} = \frac{8000}{10} = 800\,\Omega

We can also verify the result using the resistance transformation relation.

The turns ratio is

NpNs=VpVs=8000160=50\frac{N_p}{N_s} = \frac{V_p}{V_s} = \frac{8000}{160} = 50

Hence,

Rp=Rs(NpNs)2R_p = R_s\left(\frac{N_p}{N_s}\right)^2

Rp=0.32×502=0.32×2500=800 ΩR_p = 0.32 \times 50^2 = 0.32 \times 2500 = 800\,\Omega

Thus, the load resistance in the primary circuit is 800 Ω800\,\Omega and in the secondary circuit is 0.32 Ω0.32\,\Omega.

Answer: Option C